<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.icon-vad.co.uk/blogs/tag/spectralink/feed" rel="self" type="application/rss+xml"/><title>https://icon-vad.co.uk/ - Blog #spectralink</title><description>https://icon-vad.co.uk/ - Blog #spectralink</description><link>https://www.icon-vad.co.uk/blogs/tag/spectralink</link><lastBuildDate>Wed, 15 Apr 2026 00:25:49 +0200</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[S Series or 7000 series? - Ordering the correct handset type for your system]]></title><link>https://www.icon-vad.co.uk/blogs/post/handset-types</link><description><![CDATA[The S Series handsets are officially supported for the following controllers IP-DECT Server 400, 6500 and VIP One from software PCS22Cb which was relea ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_J9ld-kLJRmOY39NlRJggqg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_RToaqe27T6Sj-nke9ntMDQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_9L4GtDFkRn2MEhX84yQhXw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_aD66fY7PWYRx1w8AlgHyEg" data-element-type="table" class="zpelement zpelem-table "><style type="text/css"> [data-element-id="elm_aD66fY7PWYRx1w8AlgHyEg"] .zptable{ width:100% !important; } </style><div class="zptable zptable-align-left zptable-align-mobile-left zptable-align-tablet-left zptable-header- zptable-header-none zptable-cell-outline-off zptable-outline-off zptable-zebra-style-none zptable-style-none " data-width="100" data-editor="true"><table><tbody><tr><td style="width:72.505%;"> <div><p><b>Spectralink S series or 7000 series</b></p><p><br/></p><p>The Spectralink 7000 range of DECT handsets was introduced in 2010 and spanned 12 different models including budget models, office use, devices for healthcare and industry and lone worker devices. In 2024, the 7000 series was superseded by the S series, which brings a rationalised and focused set of handsets with only 3 handset models and accessories such as chargers, battery chargers, multi-c<a href="/S%20series%20or%207000%20series%20handsets.pdf" rel="" download=""></a>hargers and other accessories which are common throughout the range.</p><p><br/></p><p></p><div style="text-align:center;"><p style="margin-left:36pt;text-align:left;"><span style="font-weight:bold;">S33&nbsp;</span>– General use handset with Basic messaging</p><p style="margin-left:36pt;text-align:left;"><span style="font-weight:bold;">S35&nbsp;</span>– Rugged, Commercial grade handset with Advanced messaging</p><p style="margin-left:36pt;text-align:left;"><span style="font-weight:bold;">S37&nbsp;</span>– Rugged, Commercial grade handset with Advanced messaging and lone worker / man-down capability</p><p style="margin-left:36pt;text-align:left;"><br/></p><p style="margin-left:36pt;text-align:left;"><br/></p></div></div></td><td style="width:26.5919%;"><div style="text-align:center;"><img src="/MiniFlowchart.png" alt="Handset choice flowchart"/><a href="/S%20series%20or%207000%20series%20handsets.pdf" rel="" download="">Click here for explanatory flowchart</a></div></td></tr></tbody></table></div>
</div><div data-element-id="elm_t06ZKi6R4g0_TtSvHBMLow" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center zptext-align-mobile-center zptext-align-tablet-center " data-editor="true"><p></p><div><p style="text-align:left;">The S Series handsets are officially supported for the following controllers</p><ul><ul><li style="text-align:left;margin-left:36pt;line-height:1.2;">IP-DECT Server 400, 6500 and VIP One from software PCS22Cb which was released in Q3 2022.&nbsp;</li><li style="text-align:left;margin-left:36pt;line-height:1.5;">DECT Server 2500 and 8000 from software PCS23Ab which was released in Q1 2023</li><li style="text-align:left;margin-left:36pt;line-height:1.2;">S1000 Controller – all software versions</li></ul></ul><p style="text-align:left;"><b><span><br/></span></b></p><p style="text-align:left;"><span style="color:rgb(180, 45, 45);">The S Series handsets are not supported on controllers running older versions of software than those listed above.</span> In this scenario there are two options:</p></div><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><div><p style="text-align:justify;"><span style="text-align:left;color:rgb(45, 11, 11);">1) To use the S Series handsets, upgrade the system to the latest release of software which will require a current Software Assurance license.</span><span style="color:rgb(180, 45, 45);"><span style="text-align:left;">&nbsp;</span><span style="text-align:left;">IT IS IMPORTANT TO DISCUSS THE UPGRADE METHOD WITH ICON TECHNICAL BEFORE ATTEMPTING A FIRMWARE UPGRADE</span><span style="text-align:left;">.</span></span></p></div></blockquote><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><div><div><div><p style="text-align:left;">Software upgrades can take 2-3 hours depending on the age and software level of the controller and base stations.&nbsp; ICON can provide remote technical resource to upgrade the software. &nbsp;Talk to your account manager for more information.</p><p style="text-align:left;">2) Continue using 7000 series handsets - check with ICON for availability of 7000 series handsets</p></div></div></div></blockquote><div><div><p style="text-align:left;">&nbsp;</p><p style="text-align:left;"><span style="color:rgb(180, 45, 45);">The S Series handsets are not supported on controllers not listed above.</span> For these systems continue using the 7000 series handsets - check with ICON for availability of 7000 series handsets<span style="font-weight:bold;text-align:center;">&nbsp;</span></p><p style="font-weight:bold;">&nbsp;</p><p style="text-align:left;"><span style="color:rgb(180, 45, 45);"><strong>Important note about&nbsp;</strong><strong>Mk 1 IP DECT Base Stations</strong></span></p><p style="text-align:left;">The Mk 1 IP DECT Base Station was superseded by the Mk 2 IP DECT Base Stations in 2013. With the release of controller software PCS22Aa the Mk 1 IP DECT Base Stations are no longer supported. <span style="color:rgb(180, 45, 45);">This means that the S Series handsets are not compatible with the Mk 1 IP DECT Base Station since the minimum required software to the S Series handsets is PCS22Cc</span></p><p style="text-align:left;">&nbsp;</p><p style="text-align:left;">To confirm which version of IP Base Stations are installed at a site the easiest method is to look at the bottom of the IP Base Stations.&nbsp; </p><p style="text-align:left;">&nbsp;</p><p style="text-align:left;">MKI base stations have a single RJ45 network port.&nbsp;</p></div><p style="text-align:left;"><span><span><img width="284" height="213" src="/Thu%20Mar%2026%202026.png"/></span></span><br/></p><p style="text-align:left;"></p><div><p style="text-align:left;">MKII base stations have two ports; a&nbsp;<span>RJ45 network port and a RJ12 connector&nbsp;</span>for 8V DC power</p><p style="text-align:left;"><span><span><img width="300" height="129" src="/Thu%20Mar%2026%202026-1.png" style="width:274.37px !important;height:118px !important;max-width:100% !important;"/></span></span><br/></p><p></p><div><p style="text-align:left;">To be certain, check the label on the back of the IP DECT Base Station.&nbsp;In the example below, part number <b>0233 <span style="color:rgb(180, 45, 45);">7400&nbsp;</span></b>indicates that it is a Mk 2 IP DECT Base Station. Mk 1 IP DECT Base Stations have a part number of <b>0233</b><b><span style="color:rgb(180, 45, 45);">7300</span></b>.</p></div><p></p><span><div style="text-align:left;"><img width="483" height="313" src="/Thu%20Mar%2026%202026-2.png" style="width:293.58px !important;height:190px !important;max-width:100% !important;"/></div></span></div><p></p><p style="text-align:right;"><br/></p><p></p><p style="text-align:left;">Above all, if you are a trained engineer and you need advice please talk to your account manager who will be happy to help you.</p></div><p></p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Fri, 13 Mar 2026 17:22:09 +0000</pubDate></item></channel></rss>